Single Phase Protection Panels For Submersible Motors

Description:

These panels are equipped with connection details, a capacitor, overload protection and relay that protect the motor from overheating.

Table of featuresSingle Phase Protection Panels For Submersible Motors

Electronic Protection & Control Panels For Submersible Motors

Description:
  • Electronic board with microprocessor.
  • Low voltage input for external control with pressure switch or float for lowest permissible level .
  • Selectable Control Switch or float to control the lowest permissible level ( contact NO or NC).
  • An alarm indicator for dry operation (cos phi ) , and minimum permissible level rising or falling trend.
  • Light activation overload protection .
  • Button for selecting functions automatic / off / manual and reset the alarm.
  • Protection against overloads trends with power regulator and bright exterior alarm upon activation .
  • Delayed activation of the overload protection 4 seconds.
  • Select trigger external alarms rising or falling trend.
  • Protection against dry operation based on the factor cos phi (COS FI) with configurable cos phi 0.3 to 0.9 switch activation function.
  • Select Enable Auto Restart protection device from running dry with 4 attempts in 90 minutes ( after 5 ‘/ 20/40/90 ) . Selection for additional efforts after the first 4 with regulator adjustment intervals from 1 hour to 24 hours.
  • Insurance protection engine.
  • Insurance protection auxiliary circuits .
  • Thermoplastic outer sheath .
Table of featuresElectronic Protection & Control Panels For Submersible Motors

Electronic Protection & Control Panels 2 Submersible Motors

Description:
  • Electronic board with microprocessor.
  • Power supply 350/60Iz 230/400V ± 10%.
  • Very low voltage input for external control with level electrodes pressure switch or float .
  • Very low voltage input for external control with level electrodes pressure switch or float .
  • Works with : A ) 5- level electrodes : 1-common, 2- stops pumps , 3- pump control No1 , 4 – pump control No2 , 5- alarm .
  •  B) or with 4 FLOAT treatment: 1- stops pumps 2 No1 – pump control , pump control 3- NO 2, 4 – alarm .
  •  C) or with normal float 3 : 1- control pump No. 1, 2- check pump apparatus No. 2, 3- alarm .
  • 2 internal switches for the sockets electrode level , float wastewater or normal float .
  • Very low voltage input for external control of alarm , level electrodes / float .
  • 4 Timing for adjusting the sensitivity of the electrodes.
  • Very low voltage shutdown engine from the relatively hot button or sensor N.C.
  • Lamp operation .
  • Two lamps operating engines.
  • 2 lights activating motor protection against overload .
  • Lamp alarm for maximum permissible water level .
  • Switches for automatic / off / manual functions ( the last command has auto return )
  • Adjustable protective devices for controlling congestion and delay outage .
  • External button to restart the overload protection .
  • Switch off alarm for maximum permissible water level .
  • Alarm Output 24v-1A safely .
  • Standard Toggle 2 electric pumps ( the second pump activation with 2-second delay ) .
  • Insurance protection engine.
  • Insurance protection auxiliary circuits .
  • Thermoplastic outer sheath (up 7kw) or a metal casing (10-16kw).
  • Outputs with cable holder .
Table of featuresElectronic Protection & Control Panels 2 Submersible Motors